Module
WE-8 |
 |
 |
 |
Module WE-8 has been designed for cooperation with indicators series PUE C41H and PUE 5. It is installed inside casing of an indicator. WE-8 module is to increase functionality of a scale by additional 8 inputs and 8 outputs. Most often it is applicable in sets of silo , dosing scales, etc.
|
| |
|
Application:
Main applications of WE-8 module:
- Construction of load cell based industrial scales;
- RExtension of scale indicator functionality by additional IN/OUT sockets.
Design:
WE-8 module is equipped with optoinsulated inputs and separated galvanized outputs (reed relays). The outputs are designed for control over low voltage consumption receivers (max 50V DC, 200mA), and in particular for cooperation with external industrial controllers or controlling panels. In case control of high voltage consumption receivers is needed, it is necessary to use additional replays with acceptable maximal impedance.
The indicator has two chokes installed, one for the input cables and another for output cables. Cables length is approximately 3 meters.
It is possible to randomly configure inputs and outputs from indicator level.
WE-8 module can only be installed as factory option or by authorized RADWAG service.
|
|

|
|
|
Download:
- WE-8 Module product folder
|
|
CAUTION:
There are exceptions referring to installation of modules WE8, AN, PK1. In case of indicator series PUE C41H, it is not possible to install them simultaneously.
*) module installed
-) module installation impossible
|
|
|
|
OUTPUT parameters |
|
|
Quantity of outputs |
8 |
|
Kind of output |
reed replay tupe NO |
|
Cable cross-section |
0,14 - 0,5 mm2 |
|
Maximal switching current |
0,2A DC |
|
Maximal conducted voltage |
50V DC |
|
INPUT parameters |
|
|
Quantity of inputs |
8 |
|
Kind of input |
optoinsulated |
|
Cable cross-section |
0,14 - 0,5 mm2 |
|
Range of controlled voltage |
5 - 24V DC |
|
Dimensions |
107×42,5×22 mm |
|
|
|