| Module
of analog outputs AN |
 |
| |
|
|
 |
|
Module
of relay outputs PK1 |
 |
| |
Module which increases functionality
of the measuring indicator series PUE C41.
Module is an alternative solution for reed relay outputs, which
are parts of main board. This module is an alternative solution
for reed relays, which are parts of main board.
The outputs can be optionally configured (from indicator menu
level).
Outputs are let out through a choke. Cable length approximately
3 meters. |
| |
 |
|
| Schema
for relay outputs |
|
|
| |
| Specification: |
|
| Quantity of relays |
4 |
| Kind of outputs |
NO |
| Cut through cable wire |
0,14 ÷ 0,5mm2 |
| Contacts load carrying capacity |
230V AC - 2A, 30V DC - 2A |
|
| |
Caution: Additional module
is installed inside the measuring indicator series PUE C41H
by the manufacturer or service department
of
the manufacturer. Module is a part which extends functionality
of the indicator. It is not offered as a separate device. |
|
| |
 |
| Converter
module DP1 |
 |
| |
Module of additional converter
A/D - DP 1 which increases functionality of measuring indicator
series PUE C41H with possibility to connect second weighing
platform.
It is installed inside the casing of the measuring indicator.
One measuring indicator series PUE C41 can hold only one module
of additional A/D converter. |
| |
| |
| |
| Specification: |
|
| Maximal quantity of converter divisions
|
8 388 608 |
| OIML class |
III |
| Quantity of verifying divisions |
6 000 |
| Maximal signal increase |
19mV |
| Maximal voltage on 1 verifying
division |
3,3µV |
| Minimal voltage on 1 verifying division |
1µV |
| Minimal impedance of load cell |
90 |
| Maximal impedance of load cell |
1200 |
| Power supply on load cell |
5V |
| Connection of load cells |
4 or 6 cables + screen |
| Working temperature |
-10°C ÷ +40°C |
|
| |
Caution: Additional module
is installed inside the measuring indicator series PUE C41H
by the manufacturer or service department
of
the manufacturer. Module is a part which extends functionality
of the indicator. It is not offered as a separate device. |
|
 |
| Module
4in/4out and 8in/8out |
 |
| |
Module 4IN/4OUT for measuring
indicator series PUE C41H.
It gives access to 4 optoinsulated inputs and 4 outputs of reed
relay. Signals are let out through a cable which goes through
a choke. Cable intersection is 0,34mm2 (0,14 do 0,5 mm2).
Signals are, as standard, let out through a cable with approximate
length of 3 meters through a choke.
Module 8IN/8OUT for measuring indicator series PUE C41H.
This module is connected alternatively to an analog module AN
xxxx and relay module PK 1.
Its aim is to extend the functionality of measuring indicator
by additional 8 inputs and 8 outputs.
It is equipped with optoinsulated inputs and separate galvanized
outputs.
It allows for optional configuration of inputs and outputs (from
indicator menu level).
Caution:
If measuring indicator has installed module WE 8, it is not
possible to install at the same time analog output module AN
xxxx and/or module or relay output PK 1.
Signals are as standard let in and out through a 3 meter long
cable and through a choke. |
| |
 |
 |
|
| Schema
of reed relay |
Schema
of optoinsulated inputs |
|
|
| |
| Specification: |
|
| Quantity of inputs |
8 |
| Kind of inputs |
optoinsulated |
| Range of input voltage |
5 - 24V DC |
| Cut through cable wire |
0,14 ÷ 0,5mm2 |
| Quantity of outputs |
8 |
| Kind of outputs |
reed relay type NO |
| Diameter of cable wire |
0,14 ÷ 0,5mm2 |
| Load-carrying capacity of contacts
|
50V DC - 0,2A |
|
| |
Caution: Additional module
is installed inside the measuring indicator series PUE C41H
by the manufacturer or service department
of
the manufacturer. Module is a part which extends functionality
of the indicator. It is not offered as a separate device. |
|
 |
| Module
RS 485 RS1D |
 |
| |
Module RS 1D is an option for
output of RS 485 in measuring indicator series PUE C41H. Signals
let out through a cable and choke (4x2xAWG 26).
Standard cable length 3 meters. |
| |
Caution: Additional module
is installed inside the measuring indicator series PUE C41H
by the manufacturer or service department
of
the manufacturer. Module is a part which extends functionality
of the indicator. It is not offered as a separate device. |
|
 |
| Ethernet
Module ET 1G, ET 1D |
 |
| |
Module which increases functionality
of measuring indicator series PUE C41H.
This module allows for communication of the device with external
devices through Ethernet standard in accordance to protocol
TCP/IP 10/100 Mbit/s.
Device includes two LED diodes for signalization of operation
as:
- D2 is on when the module has created communication through
Ethernet network,
- D1 flashes if module receives or sends data independently
on communication speed 10Mbit/s or 100Mbit/s.
Module is accessible in two variants:
ET 1G : output with socket
ET 1D : cable with length approximately 3 meters let out though
a choke.
Caution: Additional module is installed inside the measuring
indicator series PUE C41H by the manufacturer or service department
of the manufacturer. Module is a part which extends functionality
of the indicator. It is not offered as a separate device. |
| |
Caution: Additional module
is installed inside the measuring indicator series PUE C41H
by the manufacturer or service department
of
the manufacturer. Module is a part which extends functionality
of the indicator. It is not offered as a separate device. |
|