Module of analog outputs AN
 
Module which increases functionality of measuring indicator series PUE C41H.

Module accessible in three options:
AN 0-10V : power output. Cable equipped with a choke and cable length 3 meters
AN 4-20mA : power output. Cable let out through a choke and cable length 3 meters
AN 0-20mA : power output. Cable let out through a choke and cable length 3 meters


 
. .
 
Specification:  
Modes 4 - 20mA , 0 - 20mA, 0 - 10V
Resolution 16 bit
Resistance of power output <500
Resistance of voltage output >400
Module power supply 24V DC (12 - 30V DC) max 40mA
 
Caution: Additional module is installed inside the measuring indicator series PUE C41H by the manufacturer or service department
              of the manufacturer. Module is a part which extends functionality of the indicator. It is not offered as a separate device.
Module of relay outputs PK1
 
Module which increases functionality of the measuring indicator series PUE C41.
Module is an alternative solution for reed relay outputs, which are parts of main board. This module is an alternative solution for reed relays, which are parts of main board.
The outputs can be optionally configured (from indicator menu level).

Outputs are let out through a choke. Cable length approximately 3 meters.
 
 
Schema for relay outputs
 
Specification:  
Quantity of relays 4
Kind of outputs NO
Cut through cable wire 0,14 ÷ 0,5mm2
Contacts load carrying capacity 230V AC - 2A, 30V DC - 2A
 
Caution: Additional module is installed inside the measuring indicator series PUE C41H by the manufacturer or service department
              of the manufacturer. Module is a part which extends functionality of the indicator. It is not offered as a separate device.
 
Converter module DP1
 
Module of additional converter A/D - DP 1 which increases functionality of measuring indicator series PUE C41H with possibility to connect second weighing platform.

It is installed inside the casing of the measuring indicator.

One measuring indicator series PUE C41 can hold only one module of additional A/D converter.
 
 
Specification:  
Maximal quantity of converter divisions 8 388 608
OIML class III
Quantity of verifying divisions 6 000
Maximal signal increase 19mV
Maximal voltage on 1 verifying division 3,3µV
Minimal voltage on 1 verifying division 1µV
Minimal impedance of load cell 90
Maximal impedance of load cell 1200
Power supply on load cell 5V
Connection of load cells 4 or 6 cables + screen
Working temperature -10°C ÷ +40°C
 
Caution: Additional module is installed inside the measuring indicator series PUE C41H by the manufacturer or service department
              of the manufacturer. Module is a part which extends functionality of the indicator. It is not offered as a separate device.
Module 4in/4out and 8in/8out
 
Module 4IN/4OUT for measuring indicator series PUE C41H.
It gives access to 4 optoinsulated inputs and 4 outputs of reed relay. Signals are let out through a cable which goes through a choke. Cable intersection is 0,34mm2 (0,14 do 0,5 mm2).
Signals are, as standard, let out through a cable with approximate length of 3 meters through a choke.
Module 8IN/8OUT for measuring indicator series PUE C41H.
This module is connected alternatively to an analog module AN xxxx and relay module PK 1.
Its aim is to extend the functionality of measuring indicator by additional 8 inputs and 8 outputs.
It is equipped with optoinsulated inputs and separate galvanized outputs.
It allows for optional configuration of inputs and outputs (from indicator menu level).

Caution:
If measuring indicator has installed module WE 8, it is not possible to install at the same time analog output module AN xxxx and/or module or relay output PK 1.

Signals are as standard let in and out through a 3 meter long cable and through a choke.
 
 
Schema of reed relay Schema of optoinsulated inputs
 
Specification:  
Quantity of inputs 8
Kind of inputs optoinsulated
Range of input voltage 5 - 24V DC
Cut through cable wire 0,14 ÷ 0,5mm2
Quantity of outputs 8
Kind of outputs reed relay type NO
Diameter of cable wire 0,14 ÷ 0,5mm2
Load-carrying capacity of contacts 50V DC - 0,2A
 
Caution: Additional module is installed inside the measuring indicator series PUE C41H by the manufacturer or service department
              of the manufacturer. Module is a part which extends functionality of the indicator. It is not offered as a separate device.
Module RS 485 RS1D
 
Module RS 1D is an option for output of RS 485 in measuring indicator series PUE C41H. Signals let out through a cable and choke (4x2xAWG 26).

Standard cable length 3 meters.
 
Caution: Additional module is installed inside the measuring indicator series PUE C41H by the manufacturer or service department
              of the manufacturer. Module is a part which extends functionality of the indicator. It is not offered as a separate device.
Ethernet Module ET 1G, ET 1D
 
Module which increases functionality of measuring indicator series PUE C41H.
This module allows for communication of the device with external devices through Ethernet standard in accordance to protocol TCP/IP 10/100 Mbit/s.
Device includes two LED diodes for signalization of operation as:
- D2 is on when the module has created communication through Ethernet network,
- D1 flashes if module receives or sends data independently on communication speed 10Mbit/s or 100Mbit/s.

Module is accessible in two variants:
ET 1G : output with socket
ET 1D : cable with length approximately 3 meters let out though a choke.

Caution: Additional module is installed inside the measuring indicator series PUE C41H by the manufacturer or service department of the manufacturer. Module is a part which extends functionality of the indicator. It is not offered as a separate device.
 
Caution: Additional module is installed inside the measuring indicator series PUE C41H by the manufacturer or service department
              of the manufacturer. Module is a part which extends functionality of the indicator. It is not offered as a separate device.
 
©2005 RADWAG USA L.L.C. All rights reserved.
All proprietor's rights do the materials placed in the server are in possession of RADWAG USA L.L.C. and are
not to be copied, processed and utilized in commercial purpose unless agreed with RADWAG USA L.L.C.